SUN120-125-130-135-136-G01P3 | 120-136kW | Three Phase | 8 MPPT

Stocks Available!
Rs. xxxxxx.xx Rs. xxxx.xx

Higher yields / Safe & Reliable / Smart / User-friendly

8 MPP trackers, Max. effiffifficiency up to 98.8%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Type II DC/AC SPD

  • Model    SUN-120K-G01P3-EU-AM8    SUN-125K-G01P3-EU-AM8    SUN-130K-G01P3-EU-AM8    SUN-135K-G01P3-EU-AM8    SUN-136K-G01P3-EU-AM8
  • PV String Input Date     Max. PV Input Power(kW)    180    187.5    195    202.5    204 Max. PV Input Voltage(V)    1100 Start-up Voltage(V)    250 MPPT voltage range(V)    200-1000
  • Rated PV Input voltage(V)    600 Max. Input Short Circuit Current (A)    60+60+60+60+60+60+60+60 Max. Operating PV Input Current(A)    40+40+40+40+40+40+40+40
  • No. of MPP Trackers/No. of Strings per MPP Tracker    8/4+4+4+4+4+4+4+4 AC Input/Output Side     Rated AC Output Active Power(kW)    120    125    130    135    136
  • Max. AC Output Apparent Power(kVA)    132    135    135    135    136 Rated AC output current (A)    181.9/174.0    189.4/181.2    197/188.5    204.6/195.7    206.1/197.2
  • . AC Output Current(A)    200/191.4    204.6/195.7    204.6/195.7    204.6/195.7    206.1/197.2
  • Rated output voltage/range (V)     220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form    3L+N+PE
  • Rated Output Grid Frequency/range(Hz)    50Hz/45Hz-55Hz   60Hz/55Hz-65Hz Power Factor Adjustment Range    0.8 leading to 0.8lagging
  • Total Current Harmonic Distortion THDi    <3% DC Injection Current    <0.5%ln Efficiency     Max. Efficiency    98.8% Euro Efficiency    98.2% MPPT Efficiency    >99%
  • Equipment Protection     DC Polarity Reverse Connection Protection    YES AC Output Overcurrent Protection    YES AC Output Overvoltage Protection    YES
  • AC Output Short Circuit Protection    YES Thermal Protection    YES DC Terminal Insulation Impedance Monitoring    YES DC Component Monitoring    YES Ground Fault Current Monitoring    YES
  • Power Network Monitoring    YES Island Protection Monitoring    YES Earth Fault Detection    YES DC Input Switch    YES Overvoltage Load Drop Protection    YES
  • Residual Current (RCD) Detection    YES
  • Surge Protection Level    TYPE II(DC),TYPE II(AC)
  • Interface     Communication Interface    RS485/RS232 /WiFi/LAN
  • General Data     Operating Temperature Range (°C)    ‘-25 to +60℃, >45℃ Derating Permissible Ambient Humidity    0~100% Permissible Altitude (m)    4000m Noise (dB)    ≤ 65 dB(A)
  • Ingress Protection(IP) Rating    IP 65 Inverter Topology    Non-Isolated Over Voltage Category    OVC II(DC),OVC III(AC)
  • Cabinet Size (WxHxD mm)    1006mm*516mm*325.5mm(Excluding connectors and brackets)
  • Weight [kg]    103 Warranty [year]  
  •  5 years Type Of Cooling    Intelligent air cooling
  • Grid Regulation    IEC 61727,IEC 62116,CEI 0-21,CEI 0-16,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
  • Safety EMC/Standard    IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4