SUN-60-70-75-80K-G | 60-80kW | Three Phase | 4 MPPT

Stocks Available!
Rs. xxxxxx.xx Rs. xxxx.xx

Higher yields / Safe & Reliable / Smart / User-friendly
The Deye 60-80K grid-connected inverter is suited for medium and large-scale commercial rooftops and ground-mounted solar PV system in which reliability and stability are important. the full series inverter has 30% DC input oversizing ratio and 10% AC output overloading ratio, offering a faster return on investment.

4 MPP tracker, Max. efficiency up to 98.7%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Type II DC/AC SPD
Anti-PID function (Optional)
AFCI function (optional)

  • Model    SUN-60K-G    SUN-70K-G    SUN-75K-G    SUN-80K-G PV
  • String Input Date     Max. PV Input Power(kW)    78    91    97.5    104 Max. PV Input Voltage(V)    1000 Start-up Voltage(V)    250 MPPT voltage range(V)    200-850
  • Rated PV Input voltage(V)    600 Max. Input Short Circuit Current (A)    60+60+60+60 Max. Operating PV Input Current(A)    40+40+40+40
  • No. of MPP Trackers/No. of Strings per MPP Tracker    4/3+3+3+3    4/4+4+4+4 AC Input/Output Side     Rated AC Output Active Power(kW)    60    70    75    80
  • Max. AC Output Apparent Power(kVA)    66    77    82.5    88 Rated AC output current (A)    90.9/87    106.1/101.5    113.6/108.7    121.2/115.9
  • Max. AC Output Current(A)    100/95.7    116.7/111.6    125/119.6    133.3/127.5 Rated output voltage/range (V)    220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form    3L+N+PE
  • Rated Output Grid Frequency/range(Hz)    50Hz/45Hz-55Hz   60Hz/55Hz-65Hz Power Factor Adjustment Range    0.8 leading to 0.8lagging Total Current Harmonic Distortion THDi    <3%
  • DC Injection Current    <0.5%ln Efficiency     Max. Efficiency    98.6%    98.7% Euro Efficiency    98.0%    98.1% MPPT Efficiency    >99%
  • Equipment Protection     DC Polarity Reverse Connection Protection    yes AC Output Overcurrent Protection    yes AC Output Overvoltage Protection    yes
  • AC Output Short Circuit Protection    yes Thermal Protection    yes DC Terminal Insulation Impedance Monitoring    yes DC Component Monitoring    yes Ground Fault Current Monitoring    yes
  • Power Network Monitoring    yes Island Protection Monitoring    yes Earth Fault Detection    yes DC Input Switch    yes Overvoltage Load Drop Protection    yes
  • Residual Current (RCD) Detection    yes Surge Protection Level    TYPE II(DC),TYPE II(AC) Interface     Communication Interface    RS485/RS232 /WiFi/LAN
  • General Data     Operating Temperature Range (°C)     -25 to +60℃, >45℃ Derating Permissible Ambient Humidity    0~100% Permissible Altitude (m)    4000m Noise (dB)    ≤ 50    ≤ 55
  • Ingress Protection(IP) Rating    IP 65 Inverter Topology    Non-Isolated Over Voltage Category    OVC II(DC),OVC III(AC)
  • Cabinet Size (WxHxD mm)    700mm*575mm*297mm(Excluding connectors and brackets)
  • Weight [kg]    60 Warranty [year] 
  •    5 years Type Of Cooling    Intelligent air cooling
  • Grid Regulation     IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
  • Safety EMC/Standard    IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4