Higher yields / Safe & Reliable / Smart / User-friendly
The Deye 60-80K grid-connected inverter is suited for medium and large-scale commercial rooftops and ground-mounted solar PV system in which reliability and stability are important. the full series inverter has 30% DC input oversizing ratio and 10% AC output overloading ratio, offering a faster return on investment.
4 MPP tracker, Max. efficiency up to 98.7%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Type II DC/AC SPD
Anti-PID function (Optional)
AFCI function (optional)
- Model SUN-60K-G SUN-70K-G SUN-75K-G SUN-80K-G PV
- String Input Date Max. PV Input Power(kW) 78 91 97.5 104 Max. PV Input Voltage(V) 1000 Start-up Voltage(V) 250 MPPT voltage range(V) 200-850
- Rated PV Input voltage(V) 600 Max. Input Short Circuit Current (A) 60+60+60+60 Max. Operating PV Input Current(A) 40+40+40+40
- No. of MPP Trackers/No. of Strings per MPP Tracker 4/3+3+3+3 4/4+4+4+4 AC Input/Output Side Rated AC Output Active Power(kW) 60 70 75 80
- Max. AC Output Apparent Power(kVA) 66 77 82.5 88 Rated AC output current (A) 90.9/87 106.1/101.5 113.6/108.7 121.2/115.9
- Max. AC Output Current(A) 100/95.7 116.7/111.6 125/119.6 133.3/127.5 Rated output voltage/range (V) 220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form 3L+N+PE
- Rated Output Grid Frequency/range(Hz) 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz Power Factor Adjustment Range 0.8 leading to 0.8lagging Total Current Harmonic Distortion THDi <3%
- DC Injection Current <0.5%ln Efficiency Max. Efficiency 98.6% 98.7% Euro Efficiency 98.0% 98.1% MPPT Efficiency >99%
- Equipment Protection DC Polarity Reverse Connection Protection yes AC Output Overcurrent Protection yes AC Output Overvoltage Protection yes
- AC Output Short Circuit Protection yes Thermal Protection yes DC Terminal Insulation Impedance Monitoring yes DC Component Monitoring yes Ground Fault Current Monitoring yes
- Power Network Monitoring yes Island Protection Monitoring yes Earth Fault Detection yes DC Input Switch yes Overvoltage Load Drop Protection yes
- Residual Current (RCD) Detection yes Surge Protection Level TYPE II(DC),TYPE II(AC) Interface Communication Interface RS485/RS232 /WiFi/LAN
- General Data Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating Permissible Ambient Humidity 0~100% Permissible Altitude (m) 4000m Noise (dB) ≤ 50 ≤ 55
- Ingress Protection(IP) Rating IP 65 Inverter Topology Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC)
- Cabinet Size (WxHxD mm) 700mm*575mm*297mm(Excluding connectors and brackets)
- Weight [kg] 60 Warranty [year]
- 5 years Type Of Cooling Intelligent air cooling
- Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
- Safety EMC/Standard IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4