SUN-30-33-35-36K-G04 | 30-36kW | Three Phase | 2 MPPT

Stocks Available!
Rs. xxxxxx.xx Rs. xxxx.xx

Higher yields / Safe & Reliable / Smart / User-friendly
This new series of three-phase output inverter has wider range of 30kw, 33kw, 36kw than the original series, at the same time still got two integrated MPPTs, allowing two-array to input from different roof orientations. In addition, it allows the system to be monitored and controlled remotely.

2 MPP tracker, Max. efficiency up to 98.6%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)

  • Model    SUN-30K-G04    SUN-33K-G04    SUN-35K-G04    SUN-36K-G04 
  • PV String Input Date     Max. PV Input Power(kW)    39    42.9    45.5    46.8
  • Max. PV Input Voltage(V)    1000 Start-up Voltage(V)    250 MPPT voltage range(V)    200-850 Rated PV Input voltage(V)    600
  • Max. Input Short Circuit Current (A)    60+60 Max. Operating PV Input Current(A)    40+40
  • No. of MPP Trackers/No. of Strings per MPP Tracker    2/3+3 AC Input/Output Side     Rated AC Output Active Power(kW)    30    33    35    36
  • Max. AC Output Apparent Power(kVA)    33    36.3    38.5    39.6 Rated AC output current (A)    45.5/43.5    50/47.8    53/50.7    54.5/52.2
  • Max. AC Output Current(A)    50/47.9    55/52.6    58.3/55.8    60/57.4
  • Rated output voltage/range (V)    220/380V, 230/400V 0.85Un-1.1Un Grid Connection Form    3L/N/PE
  • Rated Output Grid Frequency/range(Hz)    50/45-55, 60/55-65 Power Factor Adjustment Range    0.8 leading to 0.8lagging
  • Total Current Harmonic Distortion THDi    <3% DC Injection Current    <0.5%ln Efficiency     Max. Efficiency    98.6% Euro Efficiency    98.1% MPPT Efficiency    >99%
  • Equipment Protection     DC Polarity Reverse Connection Protection    yes
  • AC Output Overcurrent Protection    yes
  • AC Output Overvoltage Protection    yes
  • AC Output Short Circuit Protection    yes
  • Thermal Protection    yes
  • DC Terminal Insulation Impedance Monitoring    yes
  • DC Component Monitoring    yes
  • Ground Fault Current Monitoring    yes
  • Power Network Monitoring    yes
  • Island Protection Monitoring    yes
  • Earth Fault Detection    yes
  • DC Input Switch    yes
  • Overvoltage Load Drop Protection    yes
  • Residual Current (RCD) Detection    yes
  • Surge Protection Level    TYPE II(DC),TYPE II(AC) Interface  
  •   Communication Interface    RS485/RS232 /WiFi/LAN
  • General Data     Operating Temperature Range (°C)    -25 to +60℃, >45℃ Derating Permissible Ambient Humidity    0~100%
  • Permissible Altitude (m)    4000m Noise (dB)    ≤ 50 Ingress Protection(IP) Rating    IP 65 Inverter Topology  
  •  Non-Isolated Over Voltage Category    OVC II(DC),OVC III(AC)
  • Cabinet Size (WxHxD mm)    362mm*577mm*215mm(Excluding connectors and brackets)
  • Weight [kg]    23 Warranty [year]    5 years Type Of Cooling  
  •  Intelligent air cooling Grid Regulation    IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
  • Safety EMC/Standard    IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2