SUN-29.9/30/35/40/50K-SG01HP3-EU-BM3/4 | 29.9-50kW | Three Phase | 2/3/4 MPPT

Stocks Available!
Rs. xxxxxx.xx Rs. xxxx.xx

Higher yields / Safe & Reliable / Smart / User-friendly
SUN-29.9/30/35/40/50K-SG01HP3-EU-BM2/3/4 is a brand new series of three phase hybrid inveter supporting 160-700V HV Battery, ensuring system efficiency and less heat dissipation. With compact design and high-power density, this series supports 1.3 DC/AC ratio, saving device investment. It supports three phase unbalanced output, extending the application scenarios.

100% unbalanced output;each phase
AC couple to retrofifit existing solar system
*Max. 10 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Max. charging/discharging current of 100A
High voltage battery, higher efficiency
6 time periods for battery charging/discharging
Support storing energy from diesel generato

  • Model    SUN-29.9K-SG01HP3-EU-BM3    SUN-30K-SG01HP3 -EU-BM3    SUN-35K-SG01HP3 -EU-BM3    SUN-40K-SG01HP3 -EU-BM4    SUN-50K-SG01HP3 -EU-BM4
  • Battery Input Data     Battery Type    Lithium-ion Battery Voltage Range(V)    160-800 Max.Charging Current(A)    50+50
  • Max.Discharging Current(A)    50+50 Charging Strategy for Li-ion Battery    Self-adaption to BMS Number of battery input    2
  • PV String Input Data     Max DC Input Power(W)    38870    39000    45500    52000    65000 Max DC Input Voltage(V)    1000 Start-up Voltage(V)    180
  • MPPT Voltage Range(V)    150-850 Rated DC Input Voltage(V)    600 Max Input Short-Circuit Current(A)    55+55+55    55+55+55+55
  • Max Operating PV Input Current(A)    36+36+36    36+36+36+36 No.of MPP Trackers/No.of String Per MPP Tracker    3/2+2+2    4/2+2+2+2
  • AC Input/Output Data     Rated AC Input/Output Active Power(W)    29900    30000    35000    40000    50000
  • Max AC Input/Output Apparent Power (VA)    29900    33000    38500    44000    55000
  • Peak Power (off-grid)(W)    1.5 times of rated power,10s Rated AC Input/Output Current(A)    45.4/43.4    45.5/43.5    53.1/50.8    60.7/58.0    75.8/72.5
  • Max AC Input/Output Current(A)    45.4/43.4    50/47.9    58.4/55.8    66.7/63.8    83.4/79.8 Max. Three-phase Unbalanced Output Current(A)    60    60    60    70    83.3
  • Max Continuous AC Passthrough (grid to load)(A)    200 Rated Input/Output Voltage/Range(V)    220/380V,230/400V 0.85Un-1.1Un Grid Connection Form    3L+N+PE
  • Rated Input/Output Grid Frequency/Range    50/45-55, 60/55-65 Power Factor Adjustment Range    0.8 leading-0.8 lagging
  • Total Current Harmonic Distortion THDi    <3% (of nominal power) DC Injection Current    <0.5%ln Efficiency     Max Efficiency    97.60% Euro Efficiency    97.0% MPPT Efficiency    >99%
  • Equipment Protection     DC Polarity Reverse Connection Protection    YES AC Output Overcurrent Protection    YES AC Output Overvoltage Protection    YES AC Output Short Circuit Protection    YES Thermal Protection    YES DC Terminal Insulation Impedance Monitoring    YES
  • DC Component Monitoring    YES Ground Fault Current Monitoring    YES Power Network Monitoring    YES Island Protection Monitoring    YES Earth Fault Detection    YES DC Input Switch    YES Overvoltage Load Drop Protection    YES Residual Current (RCD) Detection    YES
  • Surge Protection Level    TYPE II(DC), TYPE II(AC) Interface  
  •   Communication Interface    WIFI, RS485, CAN
  • General Data     Operating Temperature Range    -40℃+60℃,>45℃ Derating Permissible Ambient Humidity    0-100% Permissible Altitude    2000m Noise    ≤ 65 dB(A)
  • Ingress Protection(IP) Rating    IP 65 Inverter Topology    Non-Isolated Over Voltage Category    OVC II(DC),OVC III(AC)
  • Cabinet size(W*H*D)[mm]    527*894*294(Excluding connectors and brackets)
  • Weight[kg]    80
  • Warranty    5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
  • Type Of Cooling    Intelligent air cooling
  • Grid Regulation    IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
  • Safety EMC/Standard    IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2